2026-09-15Technical
Three false trips on longitudinal tear detection, and how to clear them

Most false trips on longitudinal tear detection are not device failures. The three common causes are insufficient sensing-rope tension, mounting too close to the load point, and long foreign objects in the material stream.
The first shows up as a trip during an empty belt — retension the rope. The second occurs in the high-impact zone near the load point — move the sensing section downstream. The third is a correct trip and should be confirmed against site footage.
When investigating, record the operating state at the moment of the trip (empty or loaded, belt speed, material type) and read the output signal before replacing anything.