RIELSRIELS
All productsIntegrated protectionSafety switchesCondition monitoringCleaning & alignmentImpact & maintenance
Products/Safety switches/Bi-directional pull-cord switch
RSLS-II pull-cord switch

Bi-directional pull-cord switch RSLS-II

A stop point you can always reach

Protection
IP67
Output
2×SPDT
Trip force
70–100 N
Spacing
25–30 m

A pull-cord switch decides one thing: whether someone can stop the machine at the point where the accident happens.

RSLS-II is mounted on both sides of the conveyor frame, 25–30 m apart. The wire rope connects to the swing arm, so a pull at any point, in either direction, trips the internal travel switch and sends the stop signal.

Type II resets manually: it does not return on its own. After the fault is cleared, the reset button must be pressed before the line can run again — the equipment cannot be re-energised while the fault is still there.

Specifications

Ambient temperature
-40 °C to 50 °C
Relative humidity
0–95%
Atmospheric pressure
80–110 kPa
Electrical life
> 100,000 operations
Output
2×SPDT
Contact rating
AC380V 5A / DC24V 5A
Operating force
70–100 N
Trip range
20°–30°
Limit angle
75°
Reset
Manual (reset button)
Protection
IP67
Housing
High-strength die-cast aluminium alloy

Installation & wiring

  1. 01Fix the bracket to the conveyor frame, then mount the switch on it with M10×35 fasteners.
  2. 02Connect the plastic-coated wire rope to the swing arm and fix with rope clamps; keep it as tight as the switch allows to limit sag.
  3. 03Weld a support ring on the frame every 3 m to carry the rope.
  4. 04Keep 25–30 m between two switches; shorten the spacing on inclined sections.

Selection notes

Inclines

Shorten spacing on gradients, otherwise rope tension concentrates downhill and causes false trips.

Reset type

Type II resets manually — for applications where the line must not restart until someone confirms.

Hazardous areas

This model is not explosion-proof; a separate explosion-proof series is required.

Accessories

Bracket, support rings, rope clamps and wire rope are options, ordered separately.

Certification

Manufactured by Tangshan Xieli Conveyor Belt Equipment Co., Ltd. under an ISO 9001 quality system. Certificates cover the manufacturing series this product belongs to; originals available on request.

Questions

Will a slack rope trip the switch?+

Yes. The trip force is 70–100 N; insufficient rope tension pulls the arm down. Retension after clearing.

Can it wire straight into a PLC?+

Yes. 2×SPDT dry contacts connect to a digital input; no interposing relay needed.

What else is needed for installation?+

Bracket, support rings, rope clamps and rope are options. Two M10×35 fasteners come with the switch.

How is it reset?+

Type II is manual: clear the fault, press the reset button, and the arm returns to the working position.