Pull-cord switch with terminal box RSLS-J-II
Wire it on site without opening the body
A pull-cord switch decides one thing: whether someone can stop the machine at the point where the accident happens.
The J version adds a separate terminal box on the side of the housing. The cable enters through two glands and lands on a terminal block — no need to open the main enclosure, so the sealing around the travel switch stays untouched.
Suitable for cable diameters of 6–10 mm. Everything else matches the II version: manual reset, 25–30 m spacing, a support ring every 3 m.
Specifications
- Ambient temperature
- -40 °C to 50 °C
- Relative humidity
- 0–95%
- Atmospheric pressure
- 80–110 kPa
- Electrical life
- > 100,000 operations
- Output
- 2×SPDT
- Contact rating
- AC380V 5A / DC24V 5A
- Operating force
- 70–100 N
- Trip range
- 20°–30°
- Limit angle
- 75°
- Reset
- Manual (reset button)
- Protection
- IP67
- Cable diameter
- 6–10 mm
- Housing
- High-strength die-cast aluminium alloy
Installation & wiring
- 01Fix the bracket to the conveyor frame, then mount the switch on it with M10×35 fasteners.
- 02Run the cable through the glands into the terminal box, terminate, then tighten the glands to keep IP67.
- 03Connect the plastic-coated wire rope to the swing arm and fix with rope clamps; keep it as tight as the switch allows to limit sag.
- 04Weld a support ring on the frame every 3 m; keep 25–30 m between switches and shorten the spacing on inclines.
Selection notes
Where the cable is terminated on site and the main enclosure should stay closed.
6–10 mm outer diameter; outside that range, change the glands or the wiring method.
Shorten spacing on gradients, otherwise rope tension concentrates downhill and causes false trips.
This model is not explosion-proof; a separate explosion-proof series is required.
Certification
Manufactured by Tangshan Xieli Conveyor Belt Equipment Co., Ltd. under an ISO 9001 quality system. Certificates cover the manufacturing series this product belongs to; originals available on request.
Questions
How is the J version different?+
It adds a separate terminal box: the cable lands on a terminal block through glands, so the main enclosure is never opened. Trip parameters and mounting are the same.
What cable size fits?+
6–10 mm outer diameter. Thicker or thinner cable needs a different gland.
Can it wire straight into a PLC?+
Yes. 2×SPDT dry contacts connect to a digital input.
How is it reset?+
Manually: clear the fault, press the reset button, and the arm returns to the working position.